cGMP Steam Sterilizers
 


Prometco combine's over sixty years of custom manufacturing experience with 15 years of experience in designing and building cGMP steam sterilizers for the Pharmaceutical & Biotechnology Industries. Utilizing the latest 3D parametric and MRP software along with our lean manufacturing principles allow us to offer state-of-the-art solutions, which are unsurpassed in quality and reliability without sacrificing value. Using our standard cGMP steam sterilizer specification as the starting point, Prometco has the flexibility to encompass your specific requirements to deliver a steam sterilizer designed to fully meet your needs.

DESIGN

Chamber
Prometco sterilizers utilize chambers made entirely of 316L stainless steel for durability. A solid plate door design ensures reliable and smooth door travel. Chamber doors are restrained around all four edges for added safety and security.  Lubricant free door gaskets are standard.
 
Control Systems
The control system utilizes an industrial based Allen Bradley PLC control system for validatable repeatability and reliability. Programmable parameters are password coded and stored in the PLC memory. User-friendly touch screen operation allows for safe selection of the desired cycle.
 
cGMP Compliance
Each unit is constructed in strict compliance with current GMP requirements. 316L stainless steel piping and sanitary components, dual chamber drains, +/-0.5 temperature distribution, and 0.2 micron sanitary filters are just some of the standard features equipped.

APPLICATIONS
The sterilizer can be equipped with the necessary hardware to sterilize a wide variety of loads. Cycles include:

Prometco cGMP Steam Sterilizer


General purpose gravity cycle
Efficiently sterilizes hard goods and vented liquids. 

Vacuum Cycle
Allows removal of air from porous loads for better steam penetration.
 
Solution Cycle Air-overpressure and water in-jacket cooling
Enables faster sterilization of solutions in sealed containers. Cooling is aided by streaming air through the chamber while cooling the jacket with cooling water.
 
Rubber Stopper Cycle
Post vacuum is pulsed to remove moisture often trapped when sterilizing rubber stoppers.
 
ACCESSORIES
 
Loading Equipment
Chamber shelves, mobile carts, transfer trolleys, wire shelves and trays are available in standard or custom designs to meet all requirements.
 
Steam Generators
Integral clean steam generators can be supplied when clean steam is not available from a central source. The clean steam generators can be powered by electricity or facility steam.
 